【施耐德 Schneider 目录和宣传册】LMD_产品手册_Ethernet_法兰57-85 PDF
【施耐德 Schneider 目录和宣传册】LMD_产品手册_Ethernet_法兰57-85 PDF
LMD_产品手册_Ethernet_法兰57-85.pdf
- Important information
- Writing conventions and symbols
- 1 Introduction
- 1.1 About this manual
- 1.2 Unit overview
- 1.2.1 Lexium MDrive TCP/IP protocols
- 1.3 Components and interfaces
- 1.3.1 Components
- 1.3.2 Interfaces
- 1.4 Name plate
- 1.5 Part number identification
- 1.6 Documentation and literature references
- 2 Before you begin - safety information
- 2.1 Qualification of personnel
- 2.2 Intended use
- 2.3 Hazard categories
- 2.4 Basic information
- 2.5 Standards and terminology
- 3 Technical data
- 3.1 Certifications
- 3.2 Environmental conditions
- 3.3 Mechanical data
- 3.3.1 Degree of protection
- 3.3.2 Mounting
- 3.3.3 NEMA 23 (57 mm) dimensions
- 3.3.4 NEMA 34 (85 mm) dimensions
- 3.4 Electrical data
- 3.4.1 Supply voltage VDC at P1
- 3.4.2 Multifunction interface at P2 a & b
- 3.4.3 Ethernet interface at P3
- 3.4.4 LED indicators
- 3.5 Motor data
- 3.5.1 LMD•57 (NEMA 23) specifications
- 3.5.2 LMD•57 (NEMA 23) performance
- 3.5.3 LMD•85 (NEMA 34) specifications
- 3.5.4 LMD•85 (NEMA 34) performance
- 3.6 Conditions for UL 508C
- 4 Basics
- 4.1 Functional safety
- 4.1.1 Working with IEC 61508
- 5 Engineering
- 5.1 External power supply units
- 5.1.1 Supply voltage +VDC
- 5.1.2 Auxiliary power supply
- 5.1.3 Wiring and shielding
- 5.2 Ground design
- 5.3 Monitoring functions
- 6 Installation
- 6.1 Electromagnetic compatibility, EMC
- 6.2 Mechanical installation
- 6.3 Electrical installation
- 6.3.1 Overview of all connectors
- 6.3.2 Connection of the supply voltage VDC
- 6.3.3 Connection of the multifunction interface
- 6.3.4 Connection of the service interface
- 6.4 Checking wiring
- 7 Configuration
- 7.1 Preparing for Configuration
- 7.1.1 Installing the Lexium MDrive Software Suite
- 8 Operation
- 8.1 Basics
- 8.1.1 Overview
- 8.1.2 HMTechnology (HMT) 
- 8.1.2 Overview of motor phase current 
- 8.2 Software operation modes
- 8.2.1 Immediate (streaming command) mode (all protocols)
- 8.2.2 Program mode (MCode/TCP or MODBUS/TCP)
- 8.3 Operation by HMT modes
- 8.3.1 HMT off (bypass) (AS=0) 
- 8.3.1 HMT on (fixed current) (AS=1) 
- 8.3.2 HMT on (variable current) (AS=2) 
- 8.3.3 HMT on (torque mode) (AS=3) 
- 8.4 I/O operation
- 8.4.1 General purpose inputs
- 8.4.2 Power outputs
- 8.4.3 Analog input
- 8.4.3 Signal (Trip) output
- 9 Diagnostics and troubleshooting
- 9.1 Error indication and troubleshooting
- 9.1.1 Operation state and error indication
- 9.2 LED indicators
- 9.3 Error codes
- 10 Accessories and spare parts
- 11 Service, maintenance and disposal
- 11.1 Service address
- 11.2 Maintenance
- 11.3 Replacing units
- 11.4 Shipping, storage, disposal
- 12 Glossary
- 12.1 Units and conversion tables
- 12.1.1 Length
- 12.1.2 Mass
- 12.1.3 Force
- 12.1.4 Power
- 12.1.5 Rotation
- 12.1.6 Torque
- 12.1.7 Moment of inertia
- 12.1.8 Temperature
- 12.1.9 Conductor cross section
- 12.2 Terms and Abbreviations
理工酷提示:
如果遇到文件不能下载或其他产品问题,请添加管理员微信:ligongku001,并备注:产品反馈